| |
| |
Manholes (specification) |
The
work described within details a complete program for
manholes. This section details the methods, procedures,
materials and equipment as required to produce “A
Total System for Manholes”.
|
|
>>
Download Specification |
Pump
Stations, Wet Wells, Treatment Plants (specification) |
The
work described within details a complete program for
wet wells, treatment plants or other large wastewater
structures. This section details the methods,
procedures, materials and equipment as required to
produce “A Total System for Large Wastewater
Structures”.
|
| |
>> Download Specification |
CIGMAT
Report - University of Houston (report)
|
The objective of this
study was to evaluate the CCI Spectrum, Inc. coating
material SPECTRASHIELD LINER SYSTEM for various dry (new
construction) and wet (rehabilitation) projects in the
City of Houston. Specific objectives were as follows:
(a) to evaluate the applications and performance of coating
on a concrete surface under hydrostatic pressure of 15psi
(32 ft of water); (b) to evaluate the acid resistance
of the coated concrete and clay bricks with and without
holidays; and (c) to determine the bonding strength of
the coating material to concrete and clay bricks over
a period of time.
|
| |
>>Download the Report |
SPECTRASHIELD |
U.S. Patent 5,618,616 was issued for SpectraShield
in 1997 based on the systematic layering of polymer resins
which impart structural strength due to its “Stress
Skin Panel” effect. In addition, the multi-layers
eliminate groundwater intrusion, restore a structure’s
profile and provide a light reflecting, impervious barrier
to environmental penetration. The installation is done
by way of trenchless application (CIP) therefore causing
minimal disruption to the surrounding environment. A
seven foot deep manhole can be lined in less than one
hour. |
|
>>Download the SPECTRASHIELD
Brochure |
Addressing Denver's Manholes (article)
originally published in Trenchless Technology, Sep 2008 |
Metro Wastewater Reclamation District (MWRD) completed a large manhole rehab project that netted a total cost savings of over $500,000
|
|
>>
Download Article |
Plugging the Leaks (article)
originally published in Municipal Sewer & Water Magazine, Oct 2008
|
The SpectraShield Liner System enabled Kalamazoo, Michigan to control inflow and infiltration in their manholes.
|
|
>>
Download Article |
Manning the Manholes (article)
originally published in Trenchless Technology, Nov. 2004 |
When JEA set out to rehabilitate 300 miles
of deteriorated sewer pipeline using pipe bursting and
other trenchless methods, a second aspect of its service
area was also addressed. As poor as the sewer lines were,
the manholes weren’t in much better shape. |
| |
>>Download Article |
| |
|