Choose Language: English Deutsch
 
 
 
Manholes (specification)
The work described within details a complete program for manholes.  This section details the methods, procedures, materials and equipment as required to produce “A Total System for Manholes”.
>> Download Specification
Pump Stations, Wet Wells, Treatment Plants (specification)
The work described within details a complete program for wet wells, treatment plants or other large wastewater structures.  This section details the methods, procedures, materials and equipment as required to produce “A Total System for Large Wastewater Structures”.
  >> Download Specification
CIGMAT Report - University of Houston (report)

The objective of this study was to evaluate the CCI Spectrum, Inc. coating material SPECTRASHIELD LINER SYSTEM for various dry (new construction) and wet (rehabilitation) projects in the City of Houston. Specific objectives were as follows: (a) to evaluate the applications and performance of coating on a concrete surface under hydrostatic pressure of 15psi (32 ft of water); (b) to evaluate the acid resistance of the coated concrete and clay bricks with and without holidays; and (c) to determine the bonding strength of the coating material to concrete and clay bricks over a period of time.

  >>Download the Report
SPECTRASHIELD

U.S. Patent 5,618,616 was issued for SpectraShield in 1997 based on the systematic layering of polymer resins which impart structural strength due to its “Stress Skin Panel” effect. In addition, the multi-layers eliminate groundwater intrusion, restore a structure’s profile and provide a light reflecting, impervious barrier to environmental penetration. The installation is done by way of trenchless application (CIP) therefore causing minimal disruption to the surrounding environment. A seven foot deep manhole can be lined in less than one hour.

>>Download the SPECTRASHIELD Brochure
Addressing Denver's Manholes (article)
originally published in Trenchless Technology, Sep 2008
Metro Wastewater Reclamation District (MWRD) completed a large manhole rehab project that netted a total cost savings of over $500,000
>> Download Article
Plugging the Leaks (article)
originally published in Municipal Sewer & Water Magazine, Oct 2008

The SpectraShield Liner System enabled Kalamazoo, Michigan to control inflow and infiltration in their manholes.

>> Download Article
Manning the Manholes (article)
originally published in Trenchless Technology, Nov. 2004

When JEA set out to rehabilitate 300 miles of deteriorated sewer pipeline using pipe bursting and other trenchless methods, a second aspect of its service area was also addressed. As poor as the sewer lines were, the manholes weren’t in much better shape.

  >>Download Article
   

 

 

Privacy Policy | Terms of Use

 

Copyright © 2005- CCI Spectrum. Inc. All rights reserved